KX
·
LA2P
·
LG
·
LGH
·
LZ
Up to 30A switching in SPST and 20A switching in SPDT arrangement.
P.C.B. mounting & quick connect terminals can be used for various application.
Flanged cover can be fixed by screw or by snap-in mounting track.
Available as an open frame relay, with a snap-on dust cover or with an immersion cleanable, plastic sealed case.
UL
E156574
cUL
TUV
FIMKO
SEMKO
Used for power switching ; Electrical heater ; Air conditioning ; Ventilator ; House hold appliances ; Refrigerating ; Automobile ; etc.
Coil
Sensitivity
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
(Oħ10%)
Power Consumption(W)
Pull-in Voltage(VDC)
Drop-out Voltage(VDC)
Max. allowable Voltage (VDC)
KX
05
185
27
06
150
40
09
93
97
12
77
155
15
59
255
18
47
380
24
36
660
48
19
2560
110
8
13450
abt 0.93W
80% Max..
10% Min.
150%
KX
-
S
-
1
12
C
M
Type
Type of sealing
Number of poles
Coil voltage
Contact form
Contact
Nil
:Open
S
: Flow solder
H
: Plastic sealed
1
: 1pole
Dc
Dc 5, 6, 9
12,15,18
24,48,110
Nil
: Form A 4 pins
C
:Form C
A
:Form A
B
:Form B
N
: AgSn
S
: AgCdO
M
: AgSnOInO
Max. switched voltage : AC 250V ; DC 24V
Rating : 1A : 30A 240VAC/30VDC
Rating :
1C : 20A 240VAC/30VDC
Max. switched power : 1A: 7200VA ; 1C :4800VA
Max. switched current : 1A: 30A ; 1C :20A
Termination : Printed circuit terminals
Enclosure(94V-0 flammability ratings):
KX-S: Vented (flux tight) plastic cover
KX-H: Sealed plastic cover
Weight : about 12 grams.
Contact resistance : 100m
max.
Form : 1 form A (SPST) ;
Form :
1 form C (SPDT)
Material: Ag alloy
Max. switching rate:
300 ops/min (no load)
30 ops/min. (rated load)
Expected electrical life : 1×10
5
Expected mechanical life : 1×10
7
Minimum load : DC 10V 10mA
Storage temp. :-55°C ~ 155°C
Operating : -55°C ~ 85°C
Vibration,
Mechanical : 1.5 mm double amplitude
Operational : 10 ~ 55 Hz
Shock,
Mechanical : 100 G min.
Operational : 10 G min.
Operating humidity : 45 ~ 85 %RH
Coil temperature rise : 60°C max.
Between mutually insulated elements:
100MO min. at 500 VDC
Must release voltage : 5% of nominal voltage.
Must operate voltage: 80% of nominal voltage.
Operate time : 15 mS max.
Release time : 15 mS max.
Between open contact :
1500 VAC at 50/60 Hz for 1 min.
Between coil and contact :
1500 VAC at 50/60 Hz for 1 min.
Surge : 1000 V (1× 40 mS)
ADD:
No 93, Chiao-Ho Rd. Chung Ho City, Taipei Taiwan R.O.C. 235.
TEL: 886-2-22265017~8 ; 886-2-22254826 FAX: 886-2-22228924
Email:
klg886@ms25.hinet.net
klg.fiber@msa.hinet.net
Best view with1024X768 screen. All copyright reserved by KING LION ENTERPRISE CO., LTD. Design by
AboutNIC
.