· KX · LA2P · LG · LGH · LZ

 
  1. Plug-in terminals, easy to handle worldwide changeable. With ISO socket.
  2. 1 form A.
  3. Usage of relay in ear Compressor light starter horm.
  4. Optional mounting bracket.
  5. Small size, high capacity, rated load 70A.
UL  
cUL  
TUV  
FIMKO  
SEMKO  
For direct connection with cell motors ; Transmission etc.



Coil
Sensitivity
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
(Oħ10%)
Power Consumption(W)
Pull-in Voltage(VDC)
Drop-out Voltage(VDC)
Max. allowable Voltage (VDC)
LGH
12
150
80
24
75
320
abt 1.8W
75% Max.
5% Min.
130%
But for short time carrying current




LGH
-
S
-
1
12
C
M
F
D
P
 
 
Type
 
Type of sealing
 
Number of
poles
Coil voltage
Contact form
Contact
Cover
Coil parallel
component
Terminal
    S: Flow solder
H: Plastic sealed
 
1: 1pole
Dc 12,24
C: Form C
A: Form A
D: Form A
#87 double
M:AgSnOInO
N:AgSn
S:AgCdO
I:AgNi
Nil: Standard
F : Bracket
cover
Nil: Nil
R: Rosister
D: Diode
P: PCB
L: Plug-in

  1. Max. switched voltage : DC 14V
  2. Rating : N/O: 70aA, 14VDc
  3. Max. switched power : 540VA
  4. Max. switched current : 40A
  1. Termination : Printed circuit terminals
  2. Enclosure(94V-0 flammability ratings):
    LGH-S: Vented (flux tight) plastic cover
    LGH-H: Sealed plastic cover
  3. Weight : about 40 grams.
  1. Contact resistance : 100m max.
  2. Form : 1 form A (SPST)
  3. Material: AgSnOInO
  4. Max. switching rate:
    300 ops/min (no load)
    30 ops/min. (rated load)
  5. Expected electrical life : 1×105
  6. Expected mechanical life : 1×107
  7. Minimum load : DC 5V 10mA
  1. Operating : -30°C ~ 80°C
  2. Vibration,
    Mechanical : 1.5 mm double amplitude
    Operational : 10 ~ 55 Hz
  3. Shock,
    Mechanical : 100 G min.
    Operational : 5 G min.
  4. Operating humidity : 45 ~ 85 %RH
  5. Coil temperature rise : 60°C max.
  • Between mutually insulated elements:
    100MO min. at 500 VDC
  1. Must release voltage : 5% of nominal voltage.
  2. Must operate voltage: 75% of nominal voltage.
  3. Operate time : 10 mS max.
  4. Release time : 10 mS max.
 
  1. Between open contact :
    500 VAC at 50/60 Hz for 1 min.
  2. Between coil and contact :
    1000 VAC at 50/60 Hz for 1 min.
  3. Surge : V (1× 40 mS)
 


ADD: No 93, Chiao-Ho Rd. Chung Ho City, Taipei Taiwan R.O.C. 235.
TEL: 886-2-22265017~8 ; 886-2-22254826 FAX: 886-2-22228924
Email: klg886@ms25.hinet.net