- Max. switched voltage : AC 120V
; DC 24V
- Rating : 1A 120VAC ; 1A 24 VDC
- Max. switched power : 50VA ; 30 W
- Max. switched current : 1A
|
- Termination : Printed circuit
terminals
- Enclosure(94V-0 flammability ratings):
Vented (flux tight) plastic cover
KC-H(L)(T): Sealed plastic cover
- Weight : about 5.0 grams.
|
 |
 |
 |
- Contact resistance : 100m
max.
- Form : 2 form C (DPDT)
- Material: AgCdO
- Max. switching rate:
300 ops/min (no load)
30 ops/min. (rated load)
- Expected electrical life : 1×105
- Expected mechanical life : 1×107
- Minimum load : DC 1V 1mA
|
- Operating : -30°C ~ 80°C
Vibration,
Mechanical : 1.5 mm double amplitude
Operational : 10 ~ 55 Hz
- Shock,
Mechanical : 100 G min.
Operational : 15 G min.
- Operating humidity : 45 ~ 85 %RH
|
 |
 |
 |
- Between mutually insulated elements:
100MO min. at 500 VDC
|
- Must release voltage : 10% of
nominal voltage.
- Must operate voltage: 75% of nominal voltage.
- Operate time :
KC-L type : 6 mS max.
KC-T type : 8 mS max.
- Release time : 4 mS max.
|
 |
 |
|
- Between open contact :
500 VAC at 50/60 Hz for 1 min.
- Between coil and contact :
1000 VAC at 50/60 Hz for 1 min.
- Surge : 1500 V (1× 40 mS)
|
|
 |