· KD · KDE · KC · KE

 
  1. Small size and light weight can provide high density P.C.B. mountion.
  2. Scaled type available.
  3. Low coil power consumption of KC-T and high coil power consumption of meet user's selection.
  4. Plastic epoxy resin sealed type is prepared for washing procedure.
UL  
cUL  
TUV  
FIMKO  
SEMKO  
Telecommunication ; Domestic appliances ; Office machines ; Audio equipments ; Camera; etc.

Coil
Sensitivity
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
(Oħ10%)
Power Consumption(W)
Pull-in Voltage(VDC)
Drop-out Voltage(VDC)
Max. allowable Voltage (VDC)
KC-L
03
120
25
05
71.4
70
06
60
100
09
45
225
12
30
400
24
15
1600
48
7.5
6400
abt 0.36W
75% Max.
10% Min.
150%
KC-T
03
66.7
45
05
40
125
06
33.3
180
09
22.2
405
12
16.6
720
24
8.3
2880
abt 0.2W
75% Max.
10% Min.
150%




KC
-
S
L
-
2
12
C
 
 
Type
 
Type of sealing
Coil sensitivity
 
Number of poles
Coil voltage
Contact form
    S: Flow solder type
H: Plastic sealed type
L: Low
T: High
 
2: 2 poles
Dc 3, 5, 6, 9
12,24,48
C : Form C
M : Form A
B : Form B


  1. Max. switched voltage : AC 120V ; DC 24V
  2. Rating : 1A 120VAC ; 1A 24 VDC
  3. Max. switched power : 50VA ; 30 W
  4. Max. switched current : 1A
  1. Termination : Printed circuit terminals
  2. Enclosure(94V-0 flammability ratings):
    Vented (flux tight) plastic cover
    KC-H(L)(T): Sealed plastic cover
  3. Weight : about 5.0 grams.
  1. Contact resistance : 100m max.
  2. Form : 2 form C (DPDT)
  3. Material: AgCdO
  4. Max. switching rate:
    300 ops/min (no load)
    30 ops/min. (rated load)
  5. Expected electrical life : 1×105
  6. Expected mechanical life : 1×107
  7. Minimum load : DC 1V 1mA
  1. Operating : -30°C ~ 80°C
    Vibration,
  2. Mechanical : 1.5 mm double amplitude
    Operational : 10 ~ 55 Hz
  3. Shock,
    Mechanical : 100 G min.
    Operational : 15 G min.
  4. Operating humidity : 45 ~ 85 %RH
  • Between mutually insulated elements:
    100MO min. at 500 VDC
  1. Must release voltage : 10% of nominal voltage.
  2. Must operate voltage: 75% of nominal voltage.
  3. Operate time :
    KC-L type : 6 mS max.
    KC-T type : 8 mS max.
  4. Release time : 4 mS max.
 
  1. Between open contact :
    500 VAC at 50/60 Hz for 1 min.
  2. Between coil and contact :
    1000 VAC at 50/60 Hz for 1 min.
  3. Surge : 1500 V (1× 40 mS)
 


ADD: No 93, Chiao-Ho Rd. Chung Ho City, Taipei Taiwan R.O.C. 235.
TEL: 886-2-22265017~8 ; 886-2-22254826 FAX: 886-2-22228924
Email: klg886@ms25.hinet.net
  klg.fiber@msa.hinet.net
Best view with1024X768 screen. All copyright reserved by KING LION ENTERPRISE CO., LTD. Design by AboutNIC.