· KD · KDE · KC · KE


 
  1. Single contact type relay for middle current load is prepared for users' wide selection to meet various circuit design.
  2. 2.54 mm terminal pitch employment equal to IC's pitch.
  3. High density design available on P.C. B. with size of 16×11×11.5 mm and light weight of 3.5grams.
  4. Complete protective construction from dust and soldering flux. Also plastic epoxy resin sealed type is prepared for washing procedure.
  5. Employment of suitable plastic materials to be applied to high temperature condition and various chemical solution.
UL E156574
cUL  
TUV  
FIMKO  
SEMKO  
Telecommunication ; Domestic appliances ; Office machines ; Audio equipments ; Camera; etc.

Coil
Sensitivity
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
(Oħ10%)
Power Consumption(W)
Pull-in Voltage(VDC)
Drop-out Voltage(VDC)
Max. allowable Voltage (VDC)
KD-L
03
120
25
05
71.5
70
06
60
100
09
45
225
12
30
400
24
15
1600
abt 0.36W
75% Max.

10% Min.

130%.
KD-T
03
66.7
45
05
40
125
06
33.3
180
09
22.2
405
12
16.6
720
24
8.3
2880
abt 0.2W
75% Max.
10% Min.
130%




KD
-
H
L
-
1
12
C
 
 
Type
 
Type of sealing
Coil sensitivity
 
Number of poles
Coil voltage
Contact form
    S: Flow solder type
H: Plastic sealed type
L: Low
T: High
 
1: 1pole
Dc 3, 5, 6
9, 12,24
C : Form C
M : Form A
B : Form B

  1. Max. switched voltage : AC 120V ; DC 24V
  2. Rating : 3A 120VAC ; 3A 24 VDC
  3. Max. switched power : 360VA ; 75 W
  4. Max. switched current : 3A
  1. Termination : Printed circuit terminals
  2. Enclosure(94V-0 flammability ratings):
    KD-S: Vented (flux tight) plastic cover
    KD-H: Sealed plastic cover
  3. Weight : about 3.5 grams.
  1. Contact resistance : 100m max.
  2. Form : 1 form A (SPST) ;
    Form : 1 form C (SPDT)
  3. Material: AgCdO
  4. Max. switching rate:
    300 ops/min (no load)
    30 ops/min. (rated load)
  5. Expected electrical life : 1×105
  6. Expected mechanical life : 1×107
  7. Minimum load : DC 1V 1mA
  1. Operating : -30°C~ 70°C
  2. Vibration,
    Mechanical : 1.5 mm double amplitude
    Operational : 10 ~ 55 Hz
  3. Shock,
    Mechanical : 50 G min.
    Operational : 10 G min.
  4. Operating humidity : 45 ~ 85 %RH
  5. Coil temperature rise : 40°Cmax.
  • Between mutually insulated elements:
    100MO min. at 500 VDC
  1. Must release voltage : 10% of nominal voltage.
  2. Must operate voltage: 75% of nominal voltage.
  3. Operate time :
    L type : 5 mS max.
    T type : 10 mS max.
  4. Release time : 4 mS max.
 
  1. Between open contact :
    500 VAC at 50/60 Hz for 1 min.
  2. Between coil and contact :
    750 VAC at 50/60 Hz for 1 min.
  3. Surge : 1000 V (1× 40 mS)
 


ADD: No 93, Chiao-Ho Rd. Chung Ho City, Taipei Taiwan R.O.C. 235.
TEL: 886-2-22265017~8 ; 886-2-22254826 FAX: 886-2-22228924
Email: klg886@ms25.hinet.net
  klg.fiber@msa.hinet.net