· KD · KDE · KC · KE

 
  1. Switching capacity available by 10A in spite of small size design for high density P.C.B. technique.
  2. KE is approved by UL,cUL,TUV safety standard.
  3. Selection of plastic material for high temperature and better chemical solution performance.
UL E156574
cUL E156574
TUV R2057689
FIMKO  
SEMKO  
Domestic appliances ; Office machines ; Audio equipments ; Cars; etc.



Coil
Sensitivity
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
(Oħ10%)
Power Consumption(W)
Pull-in Voltage(VDC)
Drop-out Voltage(VDC)
Max. allowable Voltage (VDC)
KE
03
120
25
05
71.4
70
06
60
100
09
45
225
12
30
400
18
20
900
24
15
1600
48
7.5
6400
abt 0.36W
75% Max.
10% Min.
130%.




KE
-
S
-
1
12
C
 
 
Type
 
Type of sealing
 
Number of poles
Coil voltage
Contact form
    S: Flow solder type
H: Plastic sealed type
 
1: 1pole
Dc 3, 5, 6, 9
12,18,24,48
C : Form C
M : Form A
B : Form B


  1. Max. switched voltage : AC 250V ; DC 110V
  2. Rating : 10A 250VAC ; 6A 250VAC ;
    Rating : 15A 125VAC ; 10A 30 VDC
  3. Max. switched power : 1200VA ; 150 W
  4. Max. switched current : 10A
  1. Termination : Printed circuit terminals
  2. Enclosure(94V-0 flammability ratings):
    KE-S: Vented (flux tight) plastic cover
    KE-H: Sealed plastic cover
  3. Weight : about 11 grams.
  1. Contact resistance : 100m max.
  2. Form : 1 form C (SPDT)
    1 form A (SPST)
  3. Material: AgCdO
  4. Max. switching rate:
    300 ops/min (no load)
    30 ops/min. (rated load)
  5. Expected electrical life : 1×105
  6. Expected mechanical life : 1×107
  7. Minimum load : DC 5V 10mA
  1. Operating : -30°C ~ 70°C
  2. Vibration,
    Mechanical : 1.5 mm double amplitude
    Operational : 10 ~ 55 Hz
  3. Shock,
    Mechanical : 100 G min.
    Operational : 10 G min.
  4. Operating humidity : 45 ~ 85 %RH
  • Between mutually insulated elements:
    100MO min. at 500 VDC
  1. Must release voltage : 10% of nominal voltage.
  2. Must operate voltage: 75% of nominal voltage.
  3. Operate time : 10 mS max.
  4. Release time : 4 mS max.
  5. Coil temperature rise : 35°C max.
 
  1. Between open contact :
  2. 500 VAC at 50/60 Hz for 1 min.
  3. Between coil and contact :
    1000 VAC at 50/60 Hz for 1 min.
  4. Surge : 3000 V (1× 40 mS)
 


ADD: No 93, Chiao-Ho Rd. Chung Ho City, Taipei Taiwan R.O.C. 235.
TEL: 886-2-22265017~8 ; 886-2-22254826 FAX: 886-2-22228924
Email: klg886@ms25.hinet.net
  klg.fiber@msa.hinet.net
Best view with1024X768 screen. All copyright reserved by KING LION ENTERPRISE CO., LTD. Design by AboutNIC.