KB
·
KT
·
KAM
·
KAH
·
KJ
·
KJH
·
KI
·
KI2P
·
KH
·
LA1P
Switching capacity available by 13A in spite of small size design for high density P.C.B. technique.
KB/KBH is approved by UL,cUL,TUV safety standard.
Selection of plastic material for high temperature and better chemical solution performance.
10A -KB and 13A-KBH types are prepared for use wide selection.
UL
E156574
cUL
E156574
TUV
R9854355(KB)
FIMKO
0109056/01
SEMKO
16410
Domestic appliances ; Office machines ; Audio equipments ; Cars ; etc.
Coil
Sensitivity
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
(Oħ10%)
Power Consumption(W)
Pull-in Voltage(VDC)
Drop-out Voltage(VDC)
Max. allowable Voltage (VDC)
KB
KBH
03
120
25
05
73
70
06
60
100
09
45
225
12
30
400
18
20
900
24
15
1600
48
7.5
6400
abt 0.36W
75% Max.
5% Min.
130%
KB
-
S
-
1
12
C
Type (KB/KBH)
Type of sealing
Number of poles
Coil voltage
Contact form
S
: Flow solder type
H
: Plastic sealed type
1
: 1pole
Dc
3, 5, 6, 9
12,18,24,48
C
: Form C
M
: Form A
B
: Form B
Max. switched voltage : AC 250V ; DC 110V
Rating :
KB
KBH
10A 120VAC
13A 120VAC
6A 250VAC
10A 250VAC
10A 24 VDC
13A 24 VDC
15A 125VAC
5A 125VAC(TV5)
Max. switched power : 1200VA ; 150 W
Max. switched current : 10A(KB) ; 13A(KBH)
Termination : Printed circuit terminals
Enclosure(94V-0 flammability ratings):
KB/KBH-S: Vented (flux tight) plastic cover
KB/KBH-H: Sealed plastic cover
Weight : about 11 grams.
Contact resistance : 100m
max.
Form : 1 form C (SPDT)
Form :
1 form A (SPST)
Form :
1 form B
Material: KB : AgCdO
Material:
KBH : AgSnO
Max. switching rate:
300 ops/min (no load)
30 ops/min. (rated load)
Expected electrical life : 1×10
5
Expected mechanical life : 1×10
7
Minimum load : DC 5V 10mA
Operating : -30°C ~ 55°C
Operating : -30°C~ 80°C (D class)
Vibration,
Mechanical : 1.5 mm double amplitude
Operational : 10 ~ 55 Hz
Shock,
Mechanical : 100 G min.
Operational : 10 G min.
Operating humidity : 45 ~ 85 %RH
Coil temperature rise : 35°C max.
Between mutually insulated elements:
100MO min. at 500 VDC
Must release voltage : 5% of nominal voltage.
Must operate voltage: 75% of nominal voltage.
Operate time : 10 mS max.
Release time : 5 mS max.
Between open contact :
500 VAC at 50/60 Hz for 1 min.
Between coil and contact :
1000 VAC at 50/60 Hz for 1 min.
Surge : 3000 V (1× 40 mS)
ADD:
No 93, Chiao-Ho Rd. Chung Ho City, Taipei Taiwan R.O.C. 235.
TEL: 886-2-22265017~8 ; 886-2-22254826 FAX: 886-2-22228924
Email:
klg886@ms25.hinet.net
klg.fiber@msa.hinet.net
Best view with1024X768 screen. All copyright reserved by KING LION ENTERPRISE CO., LTD. Design by
AboutNIC
.