· KB · KT · KAM · KAH· KJ · KJH · KI · KI2P · KH · LA1P

 
  1. 8mm creepage distance. Surge resistance of 10,000V and dielectric strength of 5,000V are available.
  2. Meet 5,000V dielectric voltage between coil and contact TV-8 at 120VAC rating of KHT model.
  3. High sensitivity DC coil type of low power
  4. onsumption is available.
    Smaller size with 16A switching capacity is designed for high density P.C.B. mounting technique.
UL  
cUL  
TUV  
FIMKO  
SEMKO  
Cooking appliances ; Domestic appliances ; Air conditioner ; Audio equipments ; Controlling equivalent ; etc.



Coil
Sensitivity
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
(Oħ10%)
Power Consumption(W)
Pull-in Voltage(VDC)
Drop-out Voltage(VDC)
Max. allowable Voltage (VDC)
KH-L
KHT-L
03
240
12. 5
05
138.9
36
06
120
50
09
78.3
115
12
60
200
24
29.3
820
48
14.5
3300
abt 0.72W
80% Max.
5% Min.
130%
KH-T
KHT-T
03
176.5
17
05
106.4
47
06
88
68
09
58
155
12
44.4
270
18
29.5
610
24
21.8
1100
48
10.9
4400
abt 0.54W
80% Max.
5% Min.
130%





KH
-
H
L
-
1
12
S
 
 
Type
 
Type of sealing
Coil sensitivity
 
Number of poles
Coil voltage
Contact form
    S: Flow solder type
H: Plastic sealed type
L: Low
H: High
 
1: 1pole
Dc 3, 5, 6, 9
12,18,24,48
S : Form C
M : Form A
B : Form B


  1. Max. switched voltage : AC 250V ; DC 110V
  2. Rating :
    KH
    KHT
    16A 120VAC
    16A 120VAC
    16A 250VAC
    16A 250VAC
    16A 24VDC
    16A 24VDC
    TV-8 120VAC
  3. Max. switched power : KH : 2400VA ; 600W
    Max. switched power : KHT : 1600VA ; 400W
    Max. switched current : KH/KHT : 16A
    Max. switched current : KHT (TV-8) : 8A
  1. Termination : Printed circuit terminals
  2. Enclosure(94V-0 flammability ratings):
    KH/KHT-S(T)(L): Vented (flux tight) plastic cover
    KH/KHT-H(T)(L): Sealed plastic cover
  3. Weight : about 13 grams.
  1. Contact resistance : 100m max.
  2. Form : 1 form A (SPST) ;
    Form : 1 form C (SPDT)
  3. Material: AgCdO
  4. Max. switching rate:
    300 ops/min (no load)
    30 ops/min. (rated load)
  5. Expected electrical life : 1×105
  6. Expected mechanical life : 1×107
  7. Minimum load : DC 1V 1mA
  1. Operating : -30°C ~ 70°C
  2. Vibration,
    Mechanical : 1.5 mm double amplitude
    Operational : 10 ~ 55 Hz
  3. Shock,
    Mechanical : 50 G min.
    Operational : 10 G min.
  4. Operating humidity : 45 ~ 85 %RH
  5. Coil temperature rise :
    L type :45°C max.
    T type :35°Cmax.
  • Between mutually insulated elements:
    100MO min. at 500 VDC
  1. Must release voltage : 5% of nominal voltage.
  2. Must operate voltage: 80% of nominal voltage.
  3. Operate time :
    L type : 15 mS max.
    T type : 20 mS max.
  4. Release time : 4 mS max.
 
  1. Between open contact :
    1000 VAC at 50/60 Hz for 1 min.
  2. Between coil and contact :
    5000 VAC at 50/60 Hz for 1 min.
  3. Surge : 10000 V (1× 40 mS)
 


ADD: No 93, Chiao-Ho Rd. Chung Ho City, Taipei Taiwan R.O.C. 235.
TEL: 886-2-22265017~8 ; 886-2-22254826 FAX: 886-2-22228924
Email: klg886@ms25.hinet.net
  klg.fiber@msa.hinet.net
Best view with1024X768 screen. All copyright reserved by KING LION ENTERPRISE CO., LTD. Design by AboutNIC.