· KB · KT · KAM · KAH· KJ · KJH · KI · KI2P · KH · LA1P

 
  1. KI series relay covers switching capacity from 10A by 16A to comply with user's wide selection. (KI 1 pole 10A ; KIH 1 pole 16A)
  2. Conforming to UL, cUL, TUV and other foreign safety standard.
  3. The employment of suitable plastic materials is under high temperature condition and various chemical solution.
UL E156574
cUL E162053
TUV R9854029
FIMKO 16028
SEMKO 0050072/01
Cooking appliances ; Domestic appliances ; Audio equipments ; Refrigerators ; Air-conditioners ; Controlling equivalent, etc.


Coil
Sensitivity
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
(Oħ10%)
Power Consumption(W)
Pull-in Voltage(VDC)
Drop-out Voltage(VDC)
Max. allowable Voltage (VDC)
KI/KIH
03
176.5
17
05
106.4
47
06
88
68
09
58
155
12
44.4
270
18
29.5
610
24
21.8
1100
48
10.9
4400
abt 0.54W
80% Max.
5% Min.
130%





KI
-
S
-
1
12
C
 
 
Type
 
Type of sealing
 
Number of poles
Coil voltage
Contact form
    S: Flow solder type
H: Plastic sealed type
 
1: 1pole
Dc 3, 5, 6, 9
12,18,24,48
C : Form C
M : Form A
B : Form B

  1. Max. switched voltage : AC 250V ; DC 110V
  2. Rating : 10A 250VAC ; 10A 30 VDC ; TV-5 rating
  3. Max. switched power :
    KI : 1200VA ;300 W
    KIH : 1800VA ; 450W
  4. Max. switched current : 10A(KI) ; 16A(KIH)
  1. Termination : Printed circuit terminals
  2. Enclosure(94V-0 flammability ratings):
    KI/KIH-S: Vented (flux tight) plastic cover
    KI/KIH-H: Sealed plastic cover
  3. Weight : about 13 grams.
  1. Contact resistance : 100m max.
  2. Form : 1 form A (SPST)
    Form : 1 form C (SPDT)
  3. Material: AgCdO(KI);
    Material: AgSnO(KIH)
  4. Max. switching rate:
    300 ops/min (no load)
    30 ops/min. (rated load)
  5. Expected electrical life : 1×105
  6. Expected mechanical life : 1×107
  7. Minimum load : DC10V 10mA
  1. Operating : -30°C ~ 70°C
  2. Vibration,
    Mechanical : 1.5 mm double amplitude
    Operational : 10 ~ 55 Hz
  3. Shock,
    Mechanical : 100 G min.
    Operational : 10 G min.
  4. Operating humidity : 45 ~ 85 %RH
  • Between mutually insulated elements:
    100MO min. at 500 VDC
  1. Must release voltage : 5% of nominal voltage.
  2. Must operate voltage: 80% of nominal voltage.
  3. Operate time :20 mS max.
  4. Release time : 8 mS max.
 
  1. Between open contact :
    1000 VAC at 50/60 Hz for 1 min.
  2. Between coil and contact : 5000 VAC at 50/60 Hz for 1 min.
  3. Surge : 1000 V (1× 40 mS)
 


ADD: No 93, Chiao-Ho Rd. Chung Ho City, Taipei Taiwan R.O.C. 235.
TEL: 886-2-22265017~8 ; 886-2-22254826 FAX: 886-2-22228924
Email: klg886@ms25.hinet.net
  klg.fiber@msa.hinet.net
Best view with1024X768 screen. All copyright reserved by KING LION ENTERPRISE CO., LTD. Design by AboutNIC.