· KB · KT · KAM · KAH· KJ · KJH · KI · KI2P · KH · LA1P

 
  1. LA1P series relay are designed for switching capacity by 12A to comply with industrial control system use.
  2. SPST through SPDT contact arrangements.
  3. Low power consumption and both AC and DC coil available.
  4. Slim type and low profile (29×12.7×15 mm) is developed to provide end users with more flexibility in P.C.B. design.
  5. Complete protective construction from dust and soldering flux is designed.
UL  
cUL  
TUV  
FIMKO  
SEMKO  
Cooking appliances ; Domestic appliances ; Air conditioner ; Audio equipments ; Controlling equivalent ; etc.

Coil
Sensitivity
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
(Oħ10%)
Power Consumption(W)
Pull-in Voltage(VDC)
Drop-out Voltage(VDC)
Max. allowable Voltage (VDC)
LA1P
DC
06
66.7
90
12
33.3
360
24
16.7
1440
48
8.7
5520
60
8.2
7340
110
4.1
26530
abt 0.4W
80% Max
5% Min.
130%
LA1P
AC
24
31.7
350
115
6.6
8100
230
3.3
32500
abt 1.65VA
80% Max
5% Min.
130%




LA1P
-
S
-
1
12
D
C
 
 
Type
 
Type of sealing
 
Number of poles
Coil voltage
Voltage type
Contact form
    S: Flow solder type
H: Plastic sealed type
 
1: 1pole
Dc 6 ~ 110V
Ac 24,115,230V
D : DC Coil
A : AC Coil
C : Form C
M : Form A
B : Form B

  1. Max. switched voltage : AC 250V ; DC 110V
  2. Rating : 12A 250VAC ; 12A 30VDC
  3. Max. switched power :3000VA
  4. Max. switched current :12A
  1. Termination : Printed circuit terminals
  2. Enclosure(94V-0 flammability ratings):
    LA-S: Vented (flux tight) plastic cover
    LA-H: Sealed plastic cover
  3. Weight : about 15 grams.
  1. Contact resistance : 100m max.
  2. Form : 1 form A (SPST) ;
    Form : 1 form C (SPDT)
  3. Material: AgCdO
  4. Max. switching rate:
    300 ops/min (no load)
    30 ops/min. (rated load)
  5. Expected electrical life : 1×105
  6. Expected mechanical life : 1×107
  7. Minimum load : DC 5V 10mA
  1. Operating : -40°C ~ 85°C
  2. Vibration,
    Mechanical : 1.5 mm double amplitude
    Operational : 10 ~ 55 Hz
  3. Shock,
    Mechanical : 50 G min.
    Operational : 10 G min.
  4. Operating humidity : 45 ~ 85 %RH
  5. Coil temperature rise :30°C max.
  • Between mutually insulated elements:
    100MO min. at 500 VDC
  1. Must release voltage : 5% of nominal voltage.
  2. Must operate voltage: 80% of nominal voltage.
  3. Operate time :12 mS max.
  4. Release time : 8 mS max..
 
  1. Between open contact :
    1000 VAC at 50/60 Hz for 1 min.
  2. Between coil and contact :
    5000 VAC at 50/60 Hz for 1 min.
  3. Surge : 3000 V (1× 40 mS)
 


ADD: No 93, Chiao-Ho Rd. Chung Ho City, Taipei Taiwan R.O.C. 235.
TEL: 886-2-22265017~8 ; 886-2-22254826 FAX: 886-2-22228924
Email: klg886@ms25.hinet.net
  klg.fiber@msa.hinet.net
Best view with1024X768 screen. All copyright reserved by KING LION ENTERPRISE CO., LTD. Design by AboutNIC.